{"created":"2023-05-15T12:13:49.371018+00:00","id":324,"links":{},"metadata":{"_buckets":{"deposit":"22013120-473a-4399-9146-f383e17c1c84"},"_deposit":{"created_by":12,"id":"324","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"324"},"status":"published"},"_oai":{"id":"oai:junshin.repo.nii.ac.jp:00000324","sets":["1:6:82:91"]},"author_link":["472","473","474","475","476","477","478","479"],"control_number":"324","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-03-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"11","bibliographicPageEnd":"134","bibliographicPageStart":"129","bibliographic_titles":[{"bibliographic_title":"純真学園大学雑誌"},{"bibliographic_title":"Journal of Junshin Gakuen University,Faculty of Health Sciences","bibliographic_titleLang":"en"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"宮崎放射線治療技術管理研究会は,県内の放射線治療施設におけるX 線・電子線の出力測定について訪問による第三者評価を行い,各施設の品質管理状況の確認及び高エネルギー線量計測技術の均てん化を目的とした.訪問測定を行ったのは宮崎県下8施設9装置であり,2012年6月から2018年12月の約6年間である.測定したX 線エネルギーは23ビーム,電子線エネルギーは44ビームである.高エネルギーX 線・電子線の計測及び吸収線量算出は標準計測法01と12にて行った.8施設9装置のX 線エネルギー23ビームにおける出力線量の誤差は平均にて0.37% であり,最大で1.09% であった.電子線44ビームは,平均誤差は1.1% であり,最大で-2.33% となった.測定した全てのX 線,電子線量とも施設管理基準のX 線(±2%),電子線(±3%)以内であることが確認出来た.宮崎県下8施設9装置の訪問線量測定を行うことにより,出力線量の良好な品質管理が確認でき高エネルギー線量計測技術の均てん化がなされた.","subitem_description_type":"Abstract"},{"subitem_description":"The aim of this study is to determine the quality of standard dosimetry of absorbed dose in external beam radiotherapy even and equal by Miyazaki’s radiotherapy technique and management in Miyazaki prefecture. We visited eight institutions and nine linear accelerators for on-site dosimetry. We measured 23 beams of X-rays and 44 beams of electrons. The adsorbed doses of high-energy X-ray and electron beams were calculated using standard dosimetry 12. The average and maximum values of the dose difference were 0.37 % and 1.09 %, respectively, for 23 X-ray beams. In 44 beams of electrons, the average and maximum values of the dose difference were 1.1 % and - 2.33 %, respectively. It was observed that all the X-ray and electron measurement beams were within the facility tolerance of X-rays( ±2%) and electrons (±3%).By on-site dosimetry, eight institutions and nine linear accelerators were visited to ensure the quality of standard dosimetry of absorbed dose in external beam radiotherapy even and equal.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"純真学園大学"}]},"item_10002_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"純真学園大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12581584","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2186-6481","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1710308327429":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"【資料】宮崎県における外部放射線治療装置出力線量の訪問による第三者評価","subitem_title_language":"ja"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"久家, 教幸"},{"creatorName":"クガ, ノリユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"472","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"下田平, 春彦"},{"creatorName":"シモタビラ, ハルヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"473","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尻枝, 勝敏"},{"creatorName":"シリエダ, カツトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"474","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"久峩, 尚也"},{"creatorName":"クガ, ナオヤ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"475","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KUGA, Noriyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"476","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SHIMOTABIRA, Haruhiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"477","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SHIRIEDA, Katsutoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"478","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KUGA, Naoya","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"479","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2021-04-08"}],"displaytype":"detail","filename":"純真学園大学雑誌-11号_p129-134.pdf","filesize":[{"value":"2.3 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"純真学園大学雑誌-11号_p129-134","url":"https://junshin.repo.nii.ac.jp/record/324/files/純真学園大学雑誌-11号_p129-134.pdf"},"version_id":"f9705237-534d-483d-9fd0-60d811fef46a"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"品質管理","subitem_subject_scheme":"Other"},{"subitem_subject":"品質保証","subitem_subject_scheme":"Other"},{"subitem_subject":"出力線量測定","subitem_subject_scheme":"Other"},{"subitem_subject":"訪問測定","subitem_subject_scheme":"Other"},{"subitem_subject":"Quality assurance","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Quality control","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"dosimetry of absorbed dose","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"On-site dosimetry","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"【資料】宮崎県における外部放射線治療装置出力線量の訪問による第三者評価","item_type_id":"10002","owner":"12","path":["91"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2021-04-08"},"publish_date":"2021-04-08","publish_status":"0","recid":"324","relation_version_is_last":true,"title":["【資料】宮崎県における外部放射線治療装置出力線量の訪問による第三者評価"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2024-04-26T06:33:47.094507+00:00"}