{"created":"2023-05-15T12:14:02.714134+00:00","id":570,"links":{},"metadata":{"_buckets":{"deposit":"cfa4b8da-17b2-40af-bbec-b18a6814fd54"},"_deposit":{"created_by":12,"id":"570","owners":[12],"pid":{"revision_id":0,"type":"depid","value":"570"},"status":"published"},"_oai":{"id":"oai:junshin.repo.nii.ac.jp:00000570","sets":["1:6:82:93"]},"author_link":["1007","1008","1009","1010","1011","1012","1013","1014"],"control_number":"570","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-03-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"12","bibliographicPageEnd":"075","bibliographicPageStart":"067","bibliographic_titles":[{"bibliographic_title":"純真学園大学雑誌"},{"bibliographic_title":"Journal of Junshin Gakuen University,Faculty of Health Sciences","bibliographic_titleLang":"en"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The purpose of this study was to investigate the effect and address the suitable electron energy in cross-calibration with or without an external monitor chamber. First, using the two linear accelerators, the calibration factor (N_(〖D,w,Q〗_cross)^field) and absorbed dose to water calibration factor (N_(D,w)) values are compared with or without an external monitor chamber using cross-calibration in standard dosimetry 12. Next, the N_(〖D,w,Q〗_corss)^field uses five different energies (12, 15, 16, 18, and 20 MeV) for its cross-calibration. Then, 6 MeV electron absorbed dose at depth of the dose maximum (D (dmax)) is calculated. We compared to D (dmax) for the calibration factor (N_(D,w) (Co)) given by 60Co gamma radiation. The N_(〖D,w,Q〗_corss)^field is almost equal in both using and not using an external monitor chamber, the difference value of N_(〖D,w,Q〗_corss)^field was only 0.01%. Between both D (dmax) using calibration factors N_(〖D,w,Q〗_corss)^field and N_(D,w) (Co) is a significant difference (P < 0.001). Moreover, there is also a significant difference between D (dmax) using calibration factor obtained from 20 MeV and each 12 MeV, 15 MeV (P < 0.05). These results demonstrate that there is no significant change with or without the external monitor chamber. Furthermore, the electron energy most suitable for obtaining calibration factors N_(〖D,w,Q〗_corss)^field in cross-calibration is found to be 20 MeV, and the absorbed dose is almost the same value at 12, 15, 16, and 18 MeV.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"純真学園大学"}]},"item_10002_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"純真学園大学"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AA12581584","subitem_source_identifier_type":"NCID"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2186-6481","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_1710308327429":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"【原著】Effect of Electron Beam Energies on the Calibration Factor in Cross-Calibration With and Without an External Monitor Chamber","subitem_title_language":"en"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"久家, 教幸"},{"creatorName":"クガ, ノリユキ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"1007","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"尻枝, 勝敏"},{"creatorName":"シリエダ, カツトシ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"1008","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"下田平, 春彦"},{"creatorName":"シモタビラ, ハルヒコ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"1009","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"下野, 哲範"},{"creatorName":"シモノ, テツノリ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"1010","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"KUGA, Noriyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1011","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SHIRIEDA, Katsutoshi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1012","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SHIMOTABIRA, Haruhiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1013","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"SHIMONO, Tetsunori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1014","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-03-31"}],"displaytype":"detail","filename":"純真学園大学雑誌第12号_P059-065.pdf","filesize":[{"value":"1.8 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"Effect of Electron Beam Energies on the Calibration Factor in Cross-Calibration With and Without an External Monitor Chamber","url":"https://junshin.repo.nii.ac.jp/record/570/files/純真学園大学雑誌第12号_P059-065.pdf"},"version_id":"b63ee8d6-0965-4359-bd34-d53ccf9d5796"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"cross-calibration","subitem_subject_scheme":"Other"},{"subitem_subject":"electron beam dosimetry","subitem_subject_scheme":"Other"},{"subitem_subject":"electron beam energy","subitem_subject_scheme":"Other"},{"subitem_subject":"external monitor chamber","subitem_subject_scheme":"Other"},{"subitem_subject":"cross-calibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electron beam dosimetry","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"electron beam energy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"external monitor chamber","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"【原著】Effect of Electron Beam Energies on the Calibration Factor in Cross-Calibration With and Without an External Monitor Chamber","item_type_id":"10002","owner":"12","path":["93"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-03-31"},"publish_date":"2022-03-31","publish_status":"0","recid":"570","relation_version_is_last":true,"title":["【原著】Effect of Electron Beam Energies on the Calibration Factor in Cross-Calibration With and Without an External Monitor Chamber"],"weko_creator_id":"12","weko_shared_id":-1},"updated":"2024-04-26T01:38:45.792833+00:00"}