【報告】Evaluation of Semiconductor Dosimeter for Measuring Air Kerma Including Scattered Radiation
https://junshin.repo.nii.ac.jp/records/2000097
https://junshin.repo.nii.ac.jp/records/2000097474b89e0-395d-4f2e-ba4b-be1d9d13e9ae
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 紀要論文 / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2025-06-10 | |||||
タイトル | ||||||
タイトル | 【報告】Evaluation of Semiconductor Dosimeter for Measuring Air Kerma Including Scattered Radiation | |||||
言語 | en | |||||
言語 | ||||||
言語 | eng | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Semiconductor Dosimeter | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Dose optimization | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Air kerma | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | Scattered radiation | |||||
キーワード | ||||||
言語 | en | |||||
主題Scheme | Other | |||||
主題 | digital radiography | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
著者(英) | ||||||
姓名 | Takeshi, TAKAKI | |||||
言語 | en | |||||
姓 | TAKAKI | |||||
言語 | en | |||||
名 | Takeshi | |||||
言語 | en | |||||
著者(英) | ||||||
姓名 | Ryohei, KUROKI | |||||
言語 | en | |||||
姓 | KUROKI | |||||
言語 | en | |||||
名 | Ryohei | |||||
言語 | en | |||||
著者(英) | ||||||
姓名 | Yuki, FUJITA | |||||
言語 | en | |||||
姓 | FUJITA | |||||
言語 | en | |||||
名 | Yuki | |||||
言語 | en | |||||
著者(英) | ||||||
姓名 | Seiichi, MURAKAMI | |||||
言語 | en | |||||
姓 | MURAKAMI | |||||
言語 | en | |||||
名 | Seiichi | |||||
言語 | en | |||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Although complex to handle, ionization chambers are standard instruments for radiation dosimetry. This study compared two semiconductor dosimeters(the Dose Probe and Piranha 657)with an ionization chamber to evaluate the accuracy of air kerma measurements, including scattered radiation. The dose, energy, and object thickness dependence were verified using PMMA. The relative dose and error were calculated using an ionization chamber as the reference. The results showed that the Dose Probe maintained relative errors below 5% in all tests, which closely matched those of the ionization chamber. This confirmed the ability of the Dose Probe to accurately measure the absorbed dose, including the scatter radiation, suggesting its practicality for clinical use. This study validated the use of semiconductor dosimeters in clinical settings, supporting a simplified setup, potentially improving the measurement accuracy near detectors and enhancing dose management in radiographic practice. |
|||||